Panels

A panel on an outbound configuration defines how an outgoing HL7 message carries a result’s values.

Jump to a heading on this page:
Prioritizing
Institution Access
Adding
Editing
Cloning
Deactivating or Deleting
Fields

Prioritizing

Panels are displayed on the outbound configuration details page in priority order. Panels can be reordered to change their priority.

Institution Access

Panels are system-wide resources.

Adding

Panels can be added by customer support. See Add Fields for more information.

Editing

Panels can be edited by customer support. See View or Edit Details Fields for more information.

Cloning

Panels cannot be cloned.

Deactivating or Deleting

Panels can be deleted. Once deleted, a panel cannot be restored.

Fields

Panel fields are located in the following places in the RALS™ SYSTEM:

Data Table Fields

When viewing panels in a data table, the fields are defined as follows:

Field Notes
Outbound Configurations
Outbound Configuration Outbound configuration to which the panel belongs
Device Type Device type associated with the outbound configuration
Panels
Panel Key Unique identifier
Panel Active Indicates whether the panel is currently active
Panel Priority Indicates the panel’s priority in relation to other panels (based on the display order of the panels on the outbound configuration)
Panel Name Panel’s name
Panel HIS Panel Code Universal Service ID
Panel Test Types Panel’s test types
Panel Specimen Types Panel’s specimen types
Panel Specimen Type LIS Name (Override) Text that overrides specimen type’s LIS name
Panel Empty Values (Override) The string entered into Empty Values (Override) will be sent to the LIS as a parameter’s value if (1) Always Send is checked AND (2) either the parameter is not listed in the result or the parameter is listed but has an empty value AND (3) Exclude Empty is checked
Panel Notes Open text field that can be used at your discretion
Parameters Only enabled parameters are displayed in the data table
Parameter Group Common, Uncommon, or Respiratory
Parameter Name Name of the parameter
Parameter LIS Name Name used for the parameter when sent via result JSON
Parameter Required Indicates analyte must be present on the result for the panel to be matched
Parameter Exclude Empty Indicates analyte is excluded if value is empty; this will prevent a required analyte received with an empty value in the result from being matched to this panel
Parameter Always Send The string entered into Empty Values (Override) will be sent to the LIS as a parameter’s value if (1) Always Send is checked AND (2) either the parameter is not listed in the result or the parameter is listed but has an empty value AND (3) Exclude Empty is checked
Parameter Sort Order The order in which the parameters are sent; lower numbers are sent first
Add Fields

When adding a panel, the fields are defined as follows:

Field Notes
Name Panel’s name; must be unique within configuration; case-insensitive
HIS Panel Code Universal Service ID
Test Types Panel’s test types
Specimen Types Panel’s specimen types; if none are selected, then the panel can be matched to results using any specimen type
Specimen Type LIS Name (Override) Text that overrides specimen type’s LIS name
Empty Values (Override) The string entered into Empty Values (Override) will be sent to the LIS as a parameter’s value if (1) Always Send is checked AND (2) either the parameter is not listed in the result or the parameter is listed but has an empty value AND (3) Exclude Empty is checked
Notes Open text field that can be used at your discretion
Enabled Parameters List of enabled parameters for the device type available to be included in a message to LIS
LIS Name Name used for the parameter when sent via result JSON
Required Indicates analyte must be present on the result for the panel to be matched
Exclude Empty Indicates analyte is excluded if value is empty; this will prevent a required analyte received with an empty value in the result from being matched to this panel
Always Send The string entered into Empty Values (Override) will be sent to the LIS as a parameter’s value if (1) Always Send is checked AND (2) either the parameter is not listed in the result or the parameter is listed but has an empty value AND (3) Exclude Empty is checked; can be empty
Sort Order The order in which the parameters are sent; lower numbers are sent first
View or Edit Details Fields

When viewing or editing a panel’s details, the fields are defined as follows:

Field Notes
Name Panel’s name; must be unique within configuration; case-insensitive
HIS Panel Code Universal Service ID
Test Types Panel’s test types
Specimen Types Panel’s specimen types; if none are selected, then the panel can be matched to results using any specimen type
Specimen Type LIS Name (Override) Text that overrides specimen type’s LIS name
Empty Values (Override) The string entered into Empty Values (Override) will be sent to the LIS as a parameter’s value if (1) Always Send is checked AND (2) either the parameter is not listed in the result or the parameter is listed but has an empty value AND (3) Exclude Empty is checked
Notes Open text field that can be used at your discretion
Enabled Parameters List of enabled parameters for the device type available to be included in a message to LIS
LIS Name Name used for the parameter when sent via result JSON
Required Indicates analyte must be present on the result for the panel to be matched
Exclude Empty Indicates analyte is excluded if value is empty; this will prevent a required analyte received with an empty value in the result from being matched to this panel
Always Send The string entered into Empty Values (Override) will be sent to the LIS as a parameter’s value if (1) Always Send is checked AND (2) either the parameter is not listed in the result or the parameter is listed but has an empty value AND (3) Exclude Empty is checked; can be empty
Sort Order The order in which the parameters are sent; lower numbers are sent first